UL60335-2-24 Articulated Probe
Overview

The articulated probe meets the requirements of UL60335-2-24 Annex 101. DVA and figure 101. DVA.1.

UL60335-2-24 Articulated Probe

1.Introduction

The articulated probe meets the requirements of UL60335-2-24 Annex 101. DVA and figure 101. DVA.1. The probe is to hazard assessment for moving parts and probe to simulate access to hazardous parts by 3.5-4.5 year old Children’s hand.

 

2. Parameter

ItemDimension descriptionDimension (mm)
AMiddle finger length, 95 percentile55
BMiddle finger diameter, 5 percentile9.1
CHand length, 95 percentile125
DElbow to wrist length, 95 percentile165
EWrist diameter (circumference divided by pi), 5 percentile32
FForearm diameter (circumference divided by pi), 5 percentile46
GMinimum hand CLEARANCE (cone shaped hand part), 5 percentile39.1
HCone shaped part at finger attachment20
IHand breadth (flat hand part), 5 percentile48
JWrist breadth (used for the hand thickness – flat hand part), 5 percentile24
KHand breadth at finger attachment (flat hand part)36
LUpper arm length, 95 percentilea
Notes:

1 – The probes were designed with a center pin to rotate the hand with respect to the lower arm. That motion can be equivalently represented by rotating the probe.

2 – The finger “tip” is developed to match the dimensions of the UL articulated probe. The diameter from the tip to the first joint then tapers from the tip dimensions to the finger diameter. The joints are spaced equally along the finger length.

3 – The probe is designed to permit the hand to “bend” with respect to the arm using a hinge pin located 6 mm (0,24 in) from the hand length (wrist end) and the hand is restricted in bending not more than 90° with respect to the arm.

a If the upper arm is required to evaluate a part it shall consist of a flexible tube attached at the end of the lower arm, as the exact position of the elbow cannot be readily determined from the data points chosen.

 