1nF Impulse Voltage Generator
1. Introduction
The 1nF impulse voltage generator (high voltage surge generator) can meet the test requirements of IEC60065 clause 10.1 and IEC62368-1 annex D.2 (circuit 3). It’s subjected to 50 discharges at a maximum rate of 12/min, from a 1nF capacitor charged to 10KV in a test circuit, as shown in IEC60065 figure 5a and 5b and IEC62368-1 figure D.2.
2. Specification
Model | LSG-255(3C) |
Output voltage (open circuit) | 0.1KV-10KV(max)±5% |
Trigger mode | auto or manual or single |
Test times | 1~9999 |
Surge interval | 3-999s (3s is the inherent charging time of the device) |
Storage capacitor | 1nF |
Resistor | 1KΩ |
Working condition | 5℃~35℃ (temperature), 10%~75% (humidity) |
Dimension | W470mm*D500mm*H260mm |
Weight | Approximate 30KG |