30KV Electrostatic Discharge Generator
Overview

This equipment is composed by a ESD generator and a ESD gun, the test voltage can up to 30KV, which can cover all the test grades specified in standard IEC61000-4-2.

30KV Electrostatic Discharge Generator

1. Introduction

ESD simulator (ESD gun) is completely meet the requirements of IEC61000-4-2 and GB/T17626.2. The ESD generator is designed for the assessment of electrical and electronic equipment to withstand ESD performance. Electrostatic discharge generator is widely apply to the fields of industry control equipment, household appliance, chemical electronics,communication electronics,components, auto control equipment and etc.

ESD generator is to simulate electrostatic discharge. There is two test methods: contact discharge and air discharge, the test voltage extends from 0.1KV to 30KV, user can freely choose and define the test grade. The equipment consists by ESD generator, ESD gun and two electrodes (cone sharp electrode is for contact discharge, and ball sharp electrode is for air discharge). And the parameters of rising time, peak current and current at 30ns and 60ns are strictly meet the requirement of IEC61000-4-2.

 

2. Specification

ModelESD-2005QESD-2005
Output voltageContact discharge0.1-30kV ±3%0.5-30kV ±3%
Air discharge0.1-30kV ±3%0.5-30kV ±3%
Control and display methodsLCD+touch screenButton + digital tube
Storage functionYes, 1000 groups memoryNo
Holding time>5s
Polarity of output voltagePositive and negative (switchable)
Trigger mode

Single: single discharge

Counting:discharge as per the set number of discharges

20pps: 20 times/second

*/auto: Autonomous triggering (ESD-2005), Programmed automatic mode (ESD-2005Q)

Discharge interval:0.1~99.9s (0.05s @ 20pps)0.1~9.9s (0.05s @ 20pps)
Numbers of discharge:0~9999
Energy storage capacitance:150pF ±10%(replaceable)
Discharge resistance330Ω ±10%(replaceable)
Discharge electrodecone sharp electrode is for contact discharge, and ball sharp electrode is for air discharge
Waveform of contact dischargeMeet the standards of EN/IEC 61000-4-2, GB/T 17626.2
Rising time:0.8ns ±25%
First peak current7.5A ±15% @ 2kV7.5A ±15% @ 2kV
15A ±15% @ 4kV15A ±15% @ 4kV
22.5A ±15% @ 6kV22.5A ±15% @ 6kV
30A ±15% @ 8kV30A ±15% @ 8kV
Current at 30ns4.0A ±30% @ 2kV4.0A ±30% @ 2kV
8.0A ±30% @ 4kV8.0A ±30% @ 4kV
12.0A ±30% @ 6kV12.0A ±30% @ 6kV
16.0A ±30% @ 8kV16.0A ±30% @ 8kV
Current at 60ns2.0A ±30% @ 2kV2.0A ±30% @ 2kV
4.0A ±30% @ 4kV4.0A ±30% @ 4kV
6.0A ±30% @ 6kV6.0A ±30% @ 6kV
8.0A ±30% @ 8kV8.0A ±30% @ 8kV
Environment:Temperature:15°C-35°C;Humidity:30%-60%
Power supply:AC220±10%, 50/60Hz, 300W
Dimension:260mm(W)×170mm(H)×360mm(D)
Scroll to Top