High Current ARC Ignition Test Apparatus
Overview

The high current arc ignition test apparatus is designed according to IEC60950-1:2001 clause 4.7.3.6 for assessing the resistance of solid insulating material against to ignition from arcing electrical sources.

High Current ARC Ignition Test Apparatus (Model: PG-DYR) 

1.Introduction

The high current arc ignition test apparatus can meet the test requirements of IEC60950-1:2001 clause 4.7.3.6, BS/EN60950-1:2001, BS7002:2001, GB4943-2001 and UL746A, IEC60947.1:1999, GB/T14048.1-2000, IEC730.1:1993, GB14536.1-1998 and etc.. It’s used to measure and assess solid insulating material against to resistance to ignition from arcing electrical sources.
A power 240V(AC)/60Hz is to be supplied to the test electrodes (fixed electrode and movable electrode), a series (inductive-resistive) air core impedance is to be provided to yield a short circuit current of 32.5A and a power factor of 0.5. The sample is be to positioned with the electrodes making initial contact on the surface of the sample, the circuit is to be energized and the cyclic arcing started. The timing of arcs is to be adjusted to a rate of 40 arcs/min, the rate of electrode separation is to be 254±25mm/s, the test is to be continued until ignition of the sample occurs, a hole is burned through the sample, or until a total of 200 cycles has elapsed. The high-current ignition performance level is to be assigned base on the mean number of arcs to caused ignition.

 

2. Specification

Control modePLC
Station1 station
Electrodes

1). Material: copper (fixed electrode), stainless steel (movable electrode )

2). Size: 3.2mm in diameter, 152mm overall length and 300 chisel (fixed electrode), 3.2mm in diameter, 152mm overall length, 600 conical (movable electrode)

Electrode included angle45° to the horizontal
Test voltage240V
Arc ignition current32.5A±5%A (adjustable)
Arc ignition power factorCOSφ0.5±0 (adjustable)
Arc ignition speed254mm/s±25mm/s
Arc ignition frequency40 arcs/min (adjustable)
Arc times200 times (1~9999 times, digital display, presettable)
Sample size127mm*12.7mm*(2~12)mm
Power supply220V/50Hz, 10kVA
Scroll to Top