Overview

Needle flame tester is an equipment to assess the flammability of electrical and electronic products as per IEC60695-11-5(IEC60695-2-2)

Needle flame Tester (Model: NF-1)

1. Introduction

Needle flame test apparatus can meet the test requirements of IEC60695-11-5 (IEC60695-2-2). It is applicable to ignition hazard test, combustibility test of electronic industry and home electronic appliance. The equipment specifies a needle-flame test to simulate the effect of a small flame which may result from fault conditions, in order to assess product and material’s ignition risk and fire resistance by a simulation technique the fire.

The needle flame test apparatus is controlled by single chips and push buttons, the shell is made of coating metal sheet. The test apparatus is built-in air exhaust. The front panel is transparent for easy observation of the experimental process. Avoid gas leakage explosion caused by circuit leakage or short circuit, the equipment has self-contained gas flow size alarm device.

 

2. Specification

Control systemsingle chips and push buttons
Burner

Inner diameter: Φ 0.5mm ± 0.1mm

Outer diameter: ≤Φ 0.9mm

Length: 35mm,

Material: stainless steel

Burner angle450 or 900
Ignition layer

White pine board with thickness 10mm, and cover with wrapping tissue 12g/m2 ~30g/m2

Application time0-999.9s±0.1s adjustable (normally 30s)
Burning duration0-999.9s±0.1s (auto record, manual pause)
Flame height12mm ± 1mm (adjustable), Measuring with a steel ruler
Burn gas≧95% butane gas or propane gas
Flame requirementrising time from 100℃±2℃ to 700℃±3℃ should within 23.5s±1s
ThermocoupleΦ0.5mm K type thermocouple (The insulating sleeve heat resist to 1100 ℃)
Temperature sensorCopper with Φ4mm and 0.58±0.1g weight, equip with K type thermocouple
Thermal radiation baffleAutomatic masking
Safe operation interfaceautomatically power off upon open the glass window

Test space

≥ 0.5m3 , matte black background, illuminance ≤ 20Lux, exhaust hole: Φ70mm (Power on automatic work)

Test periodauto control
Pick-up trayYes
Gas calibration deviceBuilt-in temperature measuring box, gas calibration can be executed before test
AccessoriesWrapping tissue, flat smooth wooden board, height gauges and etc..
StandardIEC60695-11-5 (IEC60695-2-2), EN60695, GB/T51669.5, GB4706.1
Equipment size1000mm(W)*650mm(D)*1300mm (H)
Power supplyAC220±10%, 50Hz, 0.3KVA