Needle flame Tester (Model: NF-1)
1. Introduction
Needle flame test apparatus can meet the test requirements of IEC60695-11-5 (IEC60695-2-2). It is applicable to ignition hazard test, combustibility test of electronic industry and home electronic appliance. The equipment specifies a needle-flame test to simulate the effect of a small flame which may result from fault conditions, in order to assess product and material’s ignition risk and fire resistance by a simulation technique the fire.
The needle flame test apparatus is controlled by single chips and push buttons, the shell is made of coating metal sheet. The test apparatus is built-in air exhaust. The front panel is transparent for easy observation of the experimental process. Avoid gas leakage explosion caused by circuit leakage or short circuit, the equipment has self-contained gas flow size alarm device.
2. Specification
| Control system | single chips and push buttons |
| Burner | Inner diameter: Φ 0.5mm ± 0.1mm Outer diameter: ≤Φ 0.9mm Length: 35mm, Material: stainless steel |
| Burner angle | 450 or 900 |
| Ignition layer | White pine board with thickness 10mm, and cover with wrapping tissue 12g/m2 ~30g/m2 |
| Application time | 0-999.9s±0.1s adjustable (normally 30s) |
| Burning duration | 0-999.9s±0.1s (auto record, manual pause) |
| Flame height | 12mm ± 1mm (adjustable), Measuring with a steel ruler |
| Burn gas | ≧95% butane gas or propane gas |
| Flame requirement | rising time from 100℃±2℃ to 700℃±3℃ should within 23.5s±1s |
| Thermocouple | Φ0.5mm K type thermocouple (The insulating sleeve heat resist to 1100 ℃) |
| Temperature sensor | Copper with Φ4mm and 0.58±0.1g weight, equip with K type thermocouple |
| Thermal radiation baffle | Automatic masking |
| Safe operation interface | automatically power off upon open the glass window |
Test space | ≥ 0.5m3 , matte black background, illuminance ≤ 20Lux, exhaust hole: Φ70mm (Power on automatic work) |
| Test period | auto control |
| Pick-up tray | Yes |
| Gas calibration device | Built-in temperature measuring box, gas calibration can be executed before test |
| Accessories | Wrapping tissue, flat smooth wooden board, height gauges and etc.. |
| Standard | IEC60695-11-5 (IEC60695-2-2), EN60695, GB/T51669.5, GB4706.1 |
| Equipment size | 1000mm(W)*650mm(D)*1300mm (H) |
| Power supply | AC220±10%, 50Hz, 0.3KVA |