IEC60811-1-4 Low Temperature Impact Test Apparatus
Overview

Low temperature impact test apparatus is designed according to IEC60811-1-4 clause 8.5 and figure 1 for testing the mechanical strength of electrical cable with insulations and sheaths.

IEC60811-1-4 Low Temperature Impact Test Apparatus

1. Introduction

Low temperature impact test apparatus is designed according IEC60811-1-4 clause 8.5 and figure 1. The apparatus for impact test at a low temperature should work with low temperature chamber and it should be placed on a 40mm thick sponge rubber pad. The apparatus is to perform an impact test from 100mm to power cables, flexible cables and cords with PVC insulation and sheaths at a low temperature. The mass of the falling weight is determined by the overall diameter of the cable (see below table 1 and table 2). After the test, no cracks of the insulating sheaths shall be visible with normal or corrected vision without addition magnification.

 

2. Specification

ModelPG-LTI-2
Working Station1
Falling weight100g, 200g, 300g, 400g, 500g, 600g, 750g, 1000g, 1250g, 1500g
Falling impact height100mm
Steel blockΦ20, bottom arc: R300, 100g
Cool time>16h
Test temperatureas per the type of PVC compound
Steel supportThickness: 40mm, Weight: 10±1KG
Release modeManual, mechanical release
Standard conform toIEC60811-1-4 clause 8.5 and figure 1

Table 1: Fixed cable samples, the falling weight used in test specified in below tables:

OD mm

Falling weight

(g)

>

<&=

4.0

100

4.0

6.0

200

6.0

9.0

300

9.012.5

400

12.5

20.0

500

20.0

30.0

750

30.0

50.0

1000

50.0

75.0

1250

75.0

1500

Table 2: Samples of soft cable, soft wire and communication cable, the falling weight should be specified in below table:

OD mm

Falling weight

(g)

>

< & =

Flat cord

100

6.0

100

6.0

10.0

200

10.0

15.0

300

15.0

25.0

400

25.0

35.0

500

35.0

600