Apparatus for Checking Damage to Conductors
Overview

The apparatus for checking damage to conductors is designed to meet the test requirements of IEC60884-1:2022 clause 12.2.5 and figure 13, IEC60669-1, IEC62052-31 clause 6.9.7.3 (for flexion test).

Apparatus for Checking Damage to Conductors

1.Introduction

The apparatus for checking damage to conductors is designed to meet the test requirements of IEC60884-1:2022 clause 12.2.5 and figure 13, IEC60669-1, IEC62052-31 clause 6.9.7.3 (for flexion test). It is applied to checking if the terminal with screw clamping or screwless clamping can withstand the mechanical stress in normal use, and judging whether the design and structure of the screw clamping terminal meet the requirements of not excessively damaging the conductor when it clamps the conductor.

 

2. Specification

ModelPG-ADGPG-ADG1PG-ADG2
Control mode

Electric control

Working station

1

Working speed

10±2r/min

Bushing rotation diameter

75mm

Test time

0-99min59s (test time can be preset, and stop automatically when time up)

Configured mass0.3KG, 0.4KG, 0.7KG, 0.9KG, 1.4KG, 2.0KG0.3KG,0.4KG, 0.7KG, 0.9KG, 1.4KG, 2.0KG0.4KG, 0.7KG, 0.9KG, 1.4KG, 2.0KG, 2.9KG, 4.5KG, 6.8KG, 9.5KG
Test height260mm, 280mm260mm, 280mm, 300mm260mm, 280mm, 300mm, 320mm, 343mm
Diameter of bushing hole6.5mm, 9.5mm6.5mm, 9.5mm, 13mm6.5mm, 9.5mm, 9.4mm, 13.0mm, 14.5mm, 15.9mm
Height adjusting modeManual adjustable (250mm-600mm adjustable)
Maximum conductor cross-section it can test≤10.0mm2≤25.0mm2≤50.0mm2
Dimension and weightL530mm*D500mm*H800mm/80kgL1000mm*D400mm*H1300mm, 150kg
Working powerAC220±10%, 50/60Hz
Working condition5-35℃ (temp.), 30%-90%R.H.
Standard conform toIEC60884-1 clause 12.2.5/figure 13IEC60669-1 clause 12.2.5/figure 9IEC62052-31 clause 6.9.7.3/figure H.1
Scroll to Top