IK01 to IK10 Pendulum Hammer Test Apparatus
Overview

The pendulum hammer test apparatus is designed to meet the test requirements of IEC60068-2-75 test Eha for IK01 to IK10 testing

IK01 to IK10 Pendulum Hammer Test Apparatus

1.Introduction

The IK01 to IK10 pendulum hammer test apparatus is designed according to IEC60068-2-75 Test Eha and IEC62262 (equivalent EN62262), and can meet the test requirements of IEC60598, EN50102. The IK Code was originally defined in European Standard BS EN 50102:1995 and amended in 1998, following its adoption as an international standard (IEC 62262) in 2002, the European standard was renumbered EN 62262. The IK code is from 00 to 10, and corresponding impact energy is from 0.14J to 20J.

 

Working Principle:

This equipment can perform IK01 to IK10 tests, the swing pipe can be adjusted back and forward, left and right, and the angle also can be adjusted. The hammer for 1J and below tests is made of nylon, and the hammers for IK07 to IK10 tests are made by steel, the working principle is: the sample is placed in normal, then adjust the impact points, and position the impact device, then release the hammer to freely impact the hammer. The impact angle and impact height are adjustable.

For low energy tests (≤1J, IK01 to IK06), there will be a mounting fixture to fix the specimens as per IEC60068-2-75 clause 4.2.2, the mounting fixture is designed according to IE60068-2-75 figure D.3, and applied to fixed the specimens like switches, lampholders, covers, screw glands, plug, sockets and etc..

The test rig is made of aluminum alloy, with four wheels at the bottom, and the whole device can move freely.

 

2.Parameter

Swing Pipe

Steel pipe 1 (Length: 1000mm, outer diameter: 15.9mm, thickness: 1.5mm) for energies exceeding 2J

Steel pipe 2 (Length: 1000mm, outer diameter: 9.0mm, thickness: 0.5mm) for energies not exceeding 2J

Impact angle0~900
Lifting stroke200-1200mm
Impact hammers

Striking elements: ≤1J for IK01 to IK06 tests, made by nylon

Striking elements: 2J for IK07 test, 5J for IK08 test, 10J for IK09 test, 20J for IK10 test, made by steel,

Equivalent mass of hammers≤1J: 0.2KG, IK07: 0.5KG, IK08: 1.7KG, IK09: 5KG, IK10: 5KG, IK11: 10KG
Hammer release methodManual release
Mounting Fixtures

1). Completed designed according to IEC60068-2-75 figure D.3, applied for IK01 to IK06 tests

IK01-to-IK06-mounting-fixtures

2). Flat mounting plate for IK07 to IK10 tests, adjustable angle 0-90°, equipped with M6 screw holes

Characteristics 0f Striking Elements
Energy/J

≤1

 ±10%

2

±5%

5

±5%

10

±5%

20

±5%

50

±5%

Equivalent mass±2%kg

0.25(0.2)

0.51.755

10

Material

Nylon

steel

R/mm

10

25255050

50

D/mm

18.5 (20)

356080100

125

f/mm

6.2 (10)

7102020

25

r/mm

610

17

l/mm

Depends

sharp-of-striking-elements
Fall Height

Energy/J

0.140.2(0.3)0.35(0.4)0.50.71251020   50
Equivalent mass/kg0.25(0.2)0.25(0.2)0.25(0.2)(0.2)0.250.250 .250.51.75510
Fall height±1%mm56(100)80(150)140(200)(250)200280400400300200400

500

Degrees of protection against external mechanical impacts

IK01

IK02IK03IK04IK05IK06IK07IK08IK09IK10
0.14J0.2J0.35J0.5J0.7J1J2J5J10J

20J