JIS D0203 and IPx3/4 Comprehensive Waterproof Test Chamber
Overview

The JIS D0203 and IPX3/4 comprehensive waterproof test chamber is designed to meet the test requirements of JIS D0203 for R1/R2/S1/S2 tests and IEC60529 for IPX3/IPX4/4K tests

JIS D0203 and IPx3/4 Comprehensive Waterproof Test Chamber

1.Introduction

The waterproof test chamber is designed to meet the test requirements of JIS D0203 for R1/R2/S1/S2 tests and IEC60529 for IPX3/IPX4/4K tests. The rotating tube with 2 rain nozzles for R1/ R2 rain tests, the rotating tube with 40 spray nozzles for S1/S2 spray tests, both are strictly designed according to JISD0203. The oscillating tube for IPX3/4 testing is strictly designed according to IEC60529, the tube radius is R400 which has 25 nozzles and 0.4 diameter. This equipment puts the coil and the swing tube in a test chamber, R1, R2, S1, S2 tests can be carried out separately or simultaneously, and IPX3, IPX4, IPX4K tests can be carried out separately. A waterproof socket-outlet for specimen is attached on the wall of the test chamber to support live test, the front panel is transparent for easy observation of the experimental process.

Type

SymbolTest Purpose

Test Method

Rain TestR1

Auto parts against water direct contact

water pressure: 0.01Mpa, water flow: 1.9L/min, water temperature: ordinary temperature, test time: 10min

R2Auto parts against rain or spray water indirect contact

water pressure: 0.03Mpa, water flow: 3.2L/min, water temperature: ordinary temperature, test time: 10min

Spray TestS1Auto parts against rain or jet water direct contact

water pressure: 0.10Mpa, water flow: 24.5L/min, water temperature: ordinary temperature, test time: 30min

S2Auto parts against riptide

water pressure: 0.30Mpa, water flow: 39.2L/min, water temperature: ordinary temperature, test time: 1h

Spray TestIPX3

Enclosure against spraying water

spray±60 degrees from vertical, water flow: 0.07L/min±5% per hole, test time: 10min

IPX4

Enclosure against splashing water

spray±180 degrees from vertical, water flow: 0.07L/min±5% per hole, test time: 10min

 

2. Specification

Working Chamber dimension1000*1000*1000mm (L*D*H)
Outer Dimension1500*1380*2000mm (L*D*H)
Turntable Diameterφ400mm
Turntable Load Weight50KG
Lifting height450-750 mm
Turntable Speed1 -20r/min
Turntable titled0° or 15° (Horizontal)
Turntable rotation directionRotate forward / rotate reverse and forward alternately / intermittent rotate
Test Time0-999 min
WeightAbout 250kg
Working PowerAC 380V±10%/ 50Hz±10%, 1.0KW (3 phases 5 wires)
Power supply of specimen220V
Power1.0KW
Safety protection functionLeakage protection, water shortage protection, short circuit protection
Working temperature5℃~35℃ (temperature), ≤85% (R.H.), 86kPa~106kPa (pressure)
AccessoriesWater filter*2, test needle*100, 3-core cable*1 (3m)
Parameters of IPX3/4
Tube Radius400mm
Tube Flow

IPX3=1.1L/min; IPX4=1.8L/min

IPX4K=15L/min (0-18L/min adjustable)

PressureIPX3=80Kpa, IPX4=80Kpa; IPX4K=400Kpa (0-500Kpa adjustable)
Aperture of drop (mm)IPX3/IPX4=0.4mm, IPX4K=0.8mm
Aperture interval50mm
Tube inner diameter15mm
Tube angle120º (IPX3), 350º (IPX4) or custom setting
Tube speedBack and forth 1200*2: 4s; back and forth 3600*2:12s
Parameter of JIS D0203 R1/R2
Rain nozzleStrictly designed according to the figure of JIS D0203 standard
PressureR1=0.01MPa, R2=0.03MPa
Number of nozzles2pcs
Spray water time range0~99h59m, settable
Tube rotates around the shaft1~23r/min, adjustable
Parameter of JIS D0203 S1/S2
Spray NozzleStrictly designed according to the figure of JIS D0203 standard
Coil structure (rain nozzles+spray nozzles)JISD 0203
PressureS1=0.1MPa, S2=0.3MPa
Nozzle diameterΦ1.2mm
Number of nozzles40pcs
Spray water time range0~99h59m, settable
Tube rotates around the shaft1~23r/min, adjustable