PX9K High Temperature and High Pressure Fan Spray Nozzles Test Chamber
Overview

The fan spray nozzles test chamber is designed according to IEC60529:2013, DIN40050-9 figure 7 and ISO20653 figure 8 and 9 for IPX9 and IPX9K testing.  This equipment is to verify the physical and other related properties of road vehicles (like passenger cars, buses, tractors, motorcycles) and its parts under the conditions of high pressure and steam jet cleaning

PX9K Test Chamber with Fan Jet Nozzles

1.Introduction

IPX9K High temperature and high pressure jet spray test chamber is designed according to IEC60529:2013, DIN40050-9 figure 7 and ISO20653 figure 8 and 9. This equipment is to verify the physical and other related properties of road vehicles (like passenger cars, buses, tractors, motorcycles),  and its parts under the conditions of high pressure and steam jet cleaning. After the test, the user can judge if the performance of the product can meet the requirements or not, and then do the re-designing and improvement.

IPX9K High Pressure/Steam Water Jets Cleaning
Water projected in high pressure high temperature against the enclosure from 4 directions (0°, 30°, 60°, 90°) shall have no harmful effects. Test duration: 30s per direction. Water volume: 14~16 litres per minute. Pressure: 8000~10000 Kpa. Temperature: 80±5℃. Test distance: 100 to 150mm.

 

2. Specification

ModelIPX9K
Inner sizeL1200*D1200*H1200mm (depends on the specimen)
External sizeL1600*D1380*H2150mm
Test time30S for each position
Jet angle0°, 30°, 60°, 90°
Nozzle distance100-200mm (manual adjustable)
Numbers of jet4
Diameter of turntable400mm
Lifting mode of turntableManual adjustable (adjust height: 420~660mm)
Spray distance100-200mm (manual control)
Water pressure8000-10000Kpa
Water flow14~16L / min
Water tank50L (recyclable)
Temperature250C (room temperature), 80±5℃
Distribution impact force0.9~1.2N (water jet impact force calibration system)
Test time120s (30s/position)
Rotational speed of turntable1~10r/min(adjustable)
Bear weight of turntable50kg
Protection deviceLeakage, water break, short circuit
Working Power(V)380V/50Hz (3 phase 4 wire + protective ground wire)
Sample Power (V)220V/50Hz
Power(KW)18
Operation LanguageEnglish
Safety protection functionLeakage protection, water shortage protection, short circuit protection, phase sequence protection, over-heat protection
Working condition5℃~35℃ (temperature), ≤85% (R.H.), 86kPa~106kPa (pressure)
Scroll to Top