Single wire/Cable Vertical Flammability Test Apparatus
Overview

Single wire vertical flammability test apparatus is designed according to IEC60332-1 for assessing the flame retardancy of single cable or wire

Single Wire/Cable Vertical Flammability Test Apparatus (Model: DZ-3)

1. Introduction

Single wire vertical flammability test apparatus is designed according to IEC60332-1, GB/T18380.11, GB/T5169.14. It adopts bunsen burner and certain combustion gas, and the burning rate, after glow time, after flame time and damage length of the specimen evaluate the fire hazard.  The test apparatus is applied to evaluate the flame retardancy of single cable or wire with diameter more than 8mm or less than 8mm. It is suitable for R&D, QC departments of the industries of lighting appliance, LV appliance, household appliance, motor and etc..

 

2. Specification

Burner

Φ12mm ± 0.5mm (inner diameter) bunsen burner

Φ9.5mm ± 0.5mm (inner diameter) bunsen burner

Burning angle450
Flame height20mm ± 2mm to 190 ± 1mm adjustable
Flame time0-999.9s± 0.1s adjustable
After flame time0-999.9s± 0.1s (auto record, manual control)
Combustion gas95% propane
Flow pressureflowmeter and voltmeter
Temperature range0-10000C
Flame temperature requiredheat up from 1000C±50C to 7000C±30C  within the time of 45s±5s
ThermocoupleΦ0.5mm K type thermocouple
Test periodAuto control
Materialstainless steel
Standard conforms toIEC60332-1-1, IEC60332-1-2, IEC60332-2-1, IEC60332-2-2
Working dimension300mm*450mm*1200mm (0.16CBM)
Outer dimension600mm*450mm*1450mm (W*D*H)