Single Wire/Cable Vertical Flammability Test Apparatus (Model: DZ-3)
1. Introduction
Single wire vertical flammability test apparatus is designed according to IEC60332-1, GB/T18380.11, GB/T5169.14. It adopts bunsen burner and certain combustion gas, and the burning rate, after glow time, after flame time and damage length of the specimen evaluate the fire hazard. The test apparatus is applied to evaluate the flame retardancy of single cable or wire with diameter more than 8mm or less than 8mm. It is suitable for R&D, QC departments of the industries of lighting appliance, LV appliance, household appliance, motor and etc..
2. Specification
Burner | Φ12mm ± 0.5mm (inner diameter) bunsen burner Φ9.5mm ± 0.5mm (inner diameter) bunsen burner |
Burning angle | 450 |
Flame height | 20mm ± 2mm to 190 ± 1mm adjustable |
Flame time | 0-999.9s± 0.1s adjustable |
After flame time | 0-999.9s± 0.1s (auto record, manual control) |
Combustion gas | 95% propane |
Flow pressure | flowmeter and voltmeter |
Temperature range | 0-10000C |
Flame temperature required | heat up from 1000C±50C to 7000C±30C within the time of 45s±5s |
Thermocouple | Φ0.5mm K type thermocouple |
Test period | Auto control |
Material | stainless steel |
Standard conforms to | IEC60332-1-1, IEC60332-1-2, IEC60332-2-1, IEC60332-2-2 |
Working dimension | 300mm*450mm*1200mm (0.16CBM) |
Outer dimension | 600mm*450mm*1450mm (W*D*H) |