IPX3 to IPX6 Comphrehensive Waterproof Test Chamber
Overview

The IPX3 to IPX6 comprehensive waterproof test chamber combines the oscillating tube with jet hose nozzles in one system, it meets the test requirement of IEC60529 regarding the IP level IPX3, IPX4, IPX5 and IPX6

IPX3 to IPX6 Comphrehensive Waterproof Test Chamber

1.Introduction

IPX3-6 waterproof test chamber combines the oscillating tube with jet hose nozzles in one system. It can meet the test requirement of IEC60529 regarding the IP level IPX3, IPX4, IPX5 and IPX6. Waterproof test simulates the conditions of splashing water, water jets and powerful water jets. The tests are applied to electronic products, luminaire, electric components, motor and house-holding appliance. The waterproof test can help to judge the products’ performance, and provide the basis for design,  improvement and inspection.

The comphrehensive waterproof test chamer mainly consists by test tunsel and test chamber. The jet nozzles are placed in the tunsel. The oscillating tube and turntable are placed on the chamber. The inner box and turntable are made of SUS304 stainless steel with thickness of 1.2mm, which can against the water impact. Built in water tank and with ball valve to control water level, the water can be recycled. The system is controlled by Panasonic PLC and 7 inch touch screen, user is easy to operate the tests.

 

2. Specification

ModelIPX36B
Control System7 inch touch screen +PLC
Inner Chamber Dimension900*900*900 (W*D*H)
Outer Dimension1350*3400*1755mm (L*D*H)
IPX3-4 Parameter
Tube Radius (mm)R400
Delivery Rate (L/min)IPX3=1.1L/min±5%, IPX4=1.8L/min±5%
Aperture of nozzles (mm)0.4
Space between Nozzles (mm)50
Inner Diameter of Tube (mm)15
Tube Angle±1200 (IPX3), ±3500 (IPX4) or user-define
Tube Speed4s for 2*1200, 12s for 2*3600
Flow Control ModeManual control
IPX5-6 Parameters
Aperture diameter of IPX5 nozzle6.3mm
Aperture diameter of IPX6 nozzle12.5mm
Delivery rate for IPX5 (L/min)12.5±0.625
Delivery rate for IPX6 (L/min)100±5
Water pressure (Mpa)Adjustable as per water flow
Distance from specimen2.5m
Nozzle Swing ModeUP-Down swing (angle, speed adjustable)
Flow Control ModeManual control
Turntable Parameters
Diameter of Turntable (mm)Ø600
Speed of Turntable1-5r/min
Height of Turntable400-700mm
ProtectionElectric leakage, hydropenia, short circuit
Working Power (V)380V /50Hz (3 phase 4 wires+ protective ground)
Power supply for specimen220V/50Hz
Power consumption (KW)3
StandardIEC60529:1989+A1:1999, GB4208-2008, GB7000.1(IPX3, IPX4, IPX5, IPX6)
Working conditions5℃~35℃ (temperature), ≤85% (R.H.), 86kPa~106kPa (pressure)
Scroll to Top