Lampholders Normal Operation Test Apparatus
Overview

The Normal Operation test Apparatus is designed according to BS EN60238 clause 18 and figure 4, and IEC60238-2017 clause 19 and figure 4, it’s used to test the lampholders E14, E27, E40 when normal use shall cause no excessive wear or other harmful effect

Lampholders Normal Operation test apparatus

1.Introduction

The Normal Operation test Apparatus can meet the test requirements of BS EN60238 clause 18 and figure 4, and IEC60238-2017 clause 19 and figure 4. The test apparatus is to test the lamp holder when normal use shall cause no excessive wear or other harmful effect. The lamp holder’s insulation and protection against accidental contact shall not be serious affected. Lings, barriers and the like shall have adequate mechanical strength and shall be reliably fixed. Temperature rise and vibration to be expected in normal use shall not cause loosening of electrical connections.

Place the specimen in the test apparatus, and screw a corresponding test caps (E14, E27, E40) in and out with a torque of 0-3Nm for 100 times at a rate of 15 times/min. After reaches the specified number of tests, it will automatically stop. After the test, the specimen shall show: 1). no wear impairing its operation. 2). no damage impairing protection against electric shock. 3). no loosening of electrical contacts. 4). no loosening of the connection between shell and dome. 5). no loosening of the set screw locking the threaded entry.

 

2. Specification

Control modePLC+touch screen
Number of working station1
DriverMotor + transmission mechanism
Test times0-999999 (settable)
Test speed15 times/min
Test capsE14, E27, E40 (as per IEC60238:2017 figure 13, figure 14, figure 15)
Torque range0.1-3Nm (0.4Nm for candle lampholder E14, 1Nm for lampholder E14, 1.5N for lampholder E27, 3N for lampholder E40)
Working PowerAC220V/50Hz
Scroll to Top