10/700μs, 5/320μs Combination Wave Lightning Surge Generator
Overview

The lightning surge generator can generate an open-circuit voltage surge 10/700μs and an open-circuit current surge 5/320μs, the combination wave surge generator is designed to meet the requirements of IEC61000-4-5 for testing the outdoor communication lines

10/700μs, 5/320μs Combination Wave Lightning Surge Generator

1. Introduction

The 10/700μs, 5/320μs combination lightning surge generator is designed to meet the test requiremesnt of  IEC61000-4-5.  The generator is to test ports intended for connection to outdoor symmetrical communication lines, like communication equipment and communication lines.

Lightning surge generator is to simulate the surge voltage caused by switching transient and lightning transient. The surge immunity test is a destructive test to found out the surge voltage effect to EUT in normal working condition. This equipment can generate an open-circuit voltage surge 10/700μs and an open-circuit current surge 5/320μs. Interfaces are provided to connect to an external oscilloscope to monitor waveforms. The effective output impedance is 40 ohm. The test voltage can be customized, user can choose and define the test levels. the voltage and current of coupling and decoupling network can be customized, and CDN can be built-in the surge generator.

 

2. Specification

Model

LSG-6K20

LSG6K10A

Control and display mode

LCD+touch screen

Button+digital tube

Energy storage capacitor20μF ±10%
Output voltage (open)0.2KV-6kV ±5%  *(Customize-able)
Front time10μs ±30%
Time to half-value700 μs ±20%
Output current (short)150A±5% (max) @40Ω
Front time5μs ±20%
Time to half-value320μs ±20%
Output polarityPositive, negative, positive and negative alternation, positive and negative cycle
Output impedance15Ω±10%, 40Ω±10%
Trigger modeAuto or manual, single
Number of surges1-99 times
Surge interval20-9999s
Capacity of built-in CDNDC 50V, 0.1A
Coupling components of CDN100Ω+90Vgas arrestor per line
Coupling modeLines to ground (T1+R1+T2+R2-PE)
Programmable test procedureBuilt-in IEC standards and user-define, with 1000 groups memories
Working environmentTemperature:15°C-35°C humidity:0%-75%
Power supplyAC220±10%, 50/60Hz
dimension470mm(W)×260mm(H)×500mm(D)
WeightAbout 30kg