Flexing Test Apparatus
Overview

Power cord flexing test apparatus designs to meet the test requirements of IEC60320-1 clause 22.3, for applying flexing test to cord of connectors and plug connectors.

Flexing Test Appratus for Testing Supply Cord

1. Introduction

Flexing test apparatus designs to meet the test requirements of IEC60320-1 clause 22.3, for applying flexing test to cord of connectors and plug connectors. The test apparatus is configure with 7 inch LCD touch screen, PLC and step motor. The flexing angle, flexing speed an test times are settable. Equip with 4KW transformer can realize the bend test for different power cord with different rated current. The clamp can adjust the swing center to meet a variety of standard requirements.

 

2. Flexing Test Procedure

Mounting the test samples with flat cords, so that the major axis of the section is parallel to the axis of oscillation. And cord is loaded with 20N / 10N mass, so that the force applied. Then, a current equal to the rated current of the connectors / plug connector is passed through the conductors, the voltage between them being equal to the rated voltage. The oscillating member is moved backwards are forwards through an angle of 90° (45° on either side of the vertical). The number of flexing being 10,000 and the rate of flexing being 60 per minute.

During the test, there shall be no interruption of the test current, and no short-circuit between conductors. After the test, the test sample shall show no damage.

 

3. Specification

Working power220V/50Hz, 300W max
Control units7 inch LCD touch screen+PLC
Load weights5N*2, 10N*2 (achieve 5N, 10N, 20N, 10N load)
Working station1 (customizable)
Station controlEach station can act independently, or two stations can be linked
Power cord on-off monitoringIndependent monitoring of each station
Oscillating speed0-70r/min
Oscillating driveStep motor
Test times0-99999 (preset-able)
Oscillating angle450 on both sides from the vertical line (900 a bend), or any desired angle as per different standards
angle indicator0-3600, made of stainless steel
Output voltage (max)250V (customizable)
Output current (max)0-16A(customizable)
Output power (max)4KW
Reference standards

IEC60320-1 clause clause 22.3 figure 7

IEC60335-1 clause 25.14 and figure 8

IEC60335-2-14  clause 25.14

IEC60601-1 clause 8.11.3. 6

IEC60884-1 clause 23.4 figure 21

AS/NZS3112 clause 2.13.12.2 and figure 2.2

BS1361-1 clause 19.5, table 2 and figure 18

flexing-test-apparatus-for-supply-cord