The relationship between IEC60529 and ISO20653

ISO 20653 is a particular standard for road vehicles, the IP codes used in this international standard are in accordance with IEC60529, except in the case of code “K”, which describle special requirements for road vehicles that are not covered by IEC60529.

 

IEC60529 is a general standard describes a system for classifying the degresss of protection provided by enclosures of most types of electrical equipment. Hoever, standard ISO20653 applies to degrees of protection (IP code) provided by enclosures of electrical equipment of road vehicles. The IP code probes are used to verify the degrees of protection against foreign objces and against access. And the IP waterproof test equipment are used to verify the degrees of protection against water. Below is a comparison table can obviously understand the difference between the two standards.

 

IEC60529 and IS020653 Comparison Table

IEC60529ISO20653Test Tools
ElementIPMeaning for protection of electrical equipmentMeaning for the protection of personElementIPMeaning for protection of electrical equipmentMeaning for the protection of person
First code element0-not protectednot protectedFirst code element0-not protected-not protectedN/AN/A
1Protected against foreign objects with diameter≥50mmProtected against access to hazardous parts with back of hand1Protected against foreign objects with diameter≥50mmProtected against access to hazardous parts with back of handTest Probe A (Access probe)
Φ50 rigid sphere with handle
Test Force: 50N±10%
Test Probe 1 (Object probe)
Φ50mm rigid sphere without handle
Test force: 50N±10%
2Protected against foreign objects with diameter≥12.5mmProtected against access to hazardous parts with finger2Protected against foreign objects with diameter≥12.5mmProtected against access to hazardous parts with fingerTest Probe B (Acess probe)
Jointed test finger
Test force: 10N±10%
Test probe 2 (Object probe)
Φ12.5mm rigid sphere without handle
Test force: 30N±10%
3Protected against foreign objects with diameter≥2.5mmProtected against access to hazardous parts with tool3Protected against foreign objects with diameter≥2.5mmProtected against access to hazardous parts with toolTest probe C (Access probe)
Rod: Φ2.5-length 100, rigid steel rod
Test force: 3N±10%
Test probe C
Rod: Φ2.5-length 100, rigid steel rod
Test force: 3N±10%
4Protected against foreign objects with diameter≥1.0mmProtected against access to hazardous parts with wire4Protected against foreign objects with diameter≥1.0mmProtected against access to hazardous parts with wireTest probe D (Access probe)
Wire: Φ1.0-length 100, rigid steel wire
Test force: 1N±10%
Test probe D
Wire: Φ1.0-length 100, rigid steel wire
Test force: 1N±10%
5-dust protectedProtected against access to hazardous parts with wire5KProtected against foreign objects with diameter≥1.0mmProtected against access to hazardous parts with wireTest probe D (Access probe)
Wire: Φ1.0-length 100, rigid steel wire
Test force: 1N±10%
Dust chamber, with or without underpressure
(use talcum power as per IEC60529, use Arizona dust as per ISO20653)
6-dust tightProtected against access to hazardous parts with wire6KProtected against foreign objects with diameter≥1.0mmProtected against access to hazardous parts with wireTest probe D (Access probe)
Wire: Φ1.0-length 100, rigid steel wire
Test force: 1N±10%
Dust chamber, with underpressure
(use talcum power as per IEC60529, use Arizona dust as per ISO20653)
Second code element0Non-ProtectedN/ASecond code element0Non-ProtectedN/AN/AN/A
1Protected against vertically falling water drops1Protected against vertically falling water dropsDrip Box Test Apparatus
2Protected against vertically falling watere drops when enclosure tilted up to 15°2Protected against vertically falling watere drops when enclosure tilted up to 15°
3Protected against spraying water3Protected against spraying waterOscillating tube or swivel tube Testing Equipment
Spray nozzle
4Protected against splashing water4Protected against splashing water
4K Protected against splash water with increased pressure
5Protected against water jets5Protected against water jetsJet nozzles Testing Equipment
6Protected against powerful water jets6Protected against powerful water jets
6KProtected against strong high-velocity water with increased pressure
7Protected against the effects of temoprary immension in water7Protected against the effects of temoprary immension in waterImmesion Tank
8Protected against the effects of continuous immersion in water8Protected against the effects of continuous immersion in waterHigh pressure immesion tank
9Protected against high pressure and tempereature water jets9KProtected against high-pressure/steam-jet cleaningFan Jet Nozzles Test Chamber
Note: The code “K” is to describe special requirements for road vehicles
IP-code-system