Plug and Socket-Outlets Test solution IEC60884-1

IEC60884-1 is a general standard for plugs and socket-outlets for household and similar purposes, either indoors or outdoors. This standard applies plugs and fixed or portable socket-outlets for AC only, with or without earthing contact, with a rated voltage greater than 50V but not exceeding 440V, and a rated current not exceeding 32A.

Test solution based on IEC60884-1 involve key assessments such as normal operation test, endurance test, mechanical strength test, temperature rising test, heating test and etc.. PEGO supplies the fully test solutions for the standard IEC 60884-1, please see the below details:

 

IEC 60884-1:2022 Clause and SubjectPEGO Model
Clause 10.1.1 test probe 12PG-TP12
Clause10.2 Accessibility of live parts during normal usePG-TPB and PG-TP11, TP-CP
Clause 10.2 Compression test (figure 6)PG-CPT
Clause10.5 Shuttered socket-outlets (figures 7 and 8)PG-TP884
Clause 12.2.5 for checking clamps damage to conductors (figure 13)PG-ADG
Clause 12.3.12 Figure 14 deflection test of screwless-type terminalsPG-ADST
Clause 13.14 Lateral strain imposed by equipment(Figure 16)PG-LSA
Clauses 10.2/24.6 compression test (Figure 6)PG-CPT
Clause 13.22 Fixing of membranesPG-TP11
Clause 14.2 Mechanical strength of pins (Figure 17)PG-NSP
Clause 14.22.3 plug torque testPG-PIT
Clause 16.2.2 Protection against access to hazardous parts and against harmful effects due to ingress of solid foreign objectsPG-TPA, PG-TPB, PG-TPC, PG-TPD, PG-TP1, PG-TP2
Clause 16.2.3 protection against harmful effects due to ingress of water (figure 19)IPX34-R400
Clause 16.3 resistance to humidityPG-THC
Clause 17.2 test for measuring the insulation resistanceRK2683B,PG-TP11
Clause 17.3 electric strength testRK2672BM

Clause 20 Breaking capacity test (figure 22)

Clause 21 Normal operation test

PG-LTR, PG-PLD
Clause 22 force necessary to withdraw the plug (figure 25, figure 26)PG-WDFA
Clause 23.2 Cord anchorage (figure 27)

PG-CRT

PG-PCT1

Clause 23.4 protection of cable entrance in the accessories (figure 28)PG-FT01
Clause 24.2 impact test with pendulum hammerIK-PD06
Clause 24.3 Tumble barrel testPG-TB31
Clause 24.5 impact test at low temperature (figure 30)PG-LTID
Clause 24.8 abrasion test on insulating sleeves of plug pins (figure 31)PG-ATA
Clause 24.11 retention test for pins (figure 33)

PG-PFA1

PG-OV

Clause 24.12 mechanical test for means for suspension of portable socket-outletsφ3mm cylindrical steel rod with R1.5mm hemispherical end
Clause 24.17 verification of grooves, holes and reverse tapers (figure 38)PG-TPC
Clause 24.18 and clause 25.5 Compression test (figure 41)PG-CTA
Clauses 25.3 and 25.4 ball-pressure test (figure 40)

PG-BPT

PG-OV

Clause 27 creepage distances, clearances and distances through sealing compoundPG-CDC
Clause 27.1.2 glow-wire testGW-1
Clause 28.1.3 test for pins with insulating sleeves (figure 43)PG-AHR
Clause 28.2 resistance to trackingTI-1
Clause 29 resistance to rustingPG-SSC
Clause 30.2 pressure test at high temperature (figure 44)PG-PTA
Clause 30.5 impact test at low temperature (figure 45)PG-LTID

 